Showing all 5 results
-
Two Pole 10A RCD MCB RCBO 30ma 4.5Ka
- Two Pole
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 10A
- Degree of Protection: IP20
- Effectively protects electric equipment against insulating failure
Download datasheet: LA210 Datasheet
-
Two Pole 16A RCD/ MCB RCBO 4.5kA
- Two Pole
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 16A
- Degree of Protection: IP20
- Effectively protects electric equipment against insulating failure
- Two Pole MCB/RCD RCBO 30ma 16A 4.5kA
Construction and Features
- Provides protection against earth fault/leakage current, short-circuit, overload and function of isolation
- Contact position indication
- Provides protection against indirect contact by human body
- Provides complementary protection against direct contact by human body
- Effectively protects electric equipment against insulating failure
- Equipped with switched neutral and phase pole
- Provides protection against over-voltage
- Provides comprehensive protection to household and commercial distribution systems
Technical Data:
- Residual current characteristics: A
- Pole No. : 1P+N
- Tripping curve: B, C, D
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 16A
- Rated Voltage: 240V AC
- Rated Frequency: 50/60Hz
- Rated residual operating current(A): 0.03, 0.1, 0.3
- Tripping duration: instantaneous ≤ 0.1s
- Electro-mechanical endurance: 4000 cycles
- Connection Terminal: pillar terminal with clamp
- Diameter of screw d(mm): M4
- Degree of Protection: IP20
- Fastening torque: 1.2N.m
- On symmetrical DIN rail 35mm
- Terminal connection height: H1= 16mm; H2= 21mm
- Over Voltage Tripping: 280V ± 5%
- Connection Capacity: Flexible Conductor 10mm²; Rigid Conductor: 16mm²
- Installation: On symmetrical DIN Rail 35mm; Panel mounting
Download datasheet: LA216 Datasheet
-
Two Pole RCD MCB RCBO 20A 4.5Ka
- Two Pole
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 20A
- Degree of Protection: IP20
- Effectively protects electric equipment against insulating failure
Download datasheet: LA220 Datasheet
Lanx is the best electrical distributors in Australia
-
Two Pole RCD MCB RCBO 25A 4.5Ka
- Two Pole
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 25A
- Degree of Protection: IP20
- Effectively protects electric equipment against insulating failure
-
Two Pole MCB/RCD RCBO 30ma 25A 4.5kA
Construction and Features
- Provides protection against earth fault/leakage current, short-circuit, overload and function of isolation
- Contact position indication
- Provides protection against indirect contact by human body
- Provides complementary protection against direct contact by human body
- Effectively protects electric equipment against insulating failure
- Equipped with switched neutral and phase pole
- Provides protection against over-voltage
- Provides comprehensive protection to household and commercial distribution systems
Technical Data:
- Residual current characteristics: A
- Pole No. : 1P+N
- Tripping curve: B, C, D
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 25A
- Rated Voltage: 240V AC
- Rated Frequency: 50/60Hz
- Rated residual operating current(A): 0.03, 0.1, 0.3
- Tripping duration: instantaneous ≤ 0.1s
- Electro-mechanical endurance: 4000 cycles
- Connection Terminal: pillar terminal with clamp
- Diameter of screw d(mm): M4
- Degree of Protection: IP20
- Fastening torque: 1.2N.m
- On symmetrical DIN rail 35mm
- Terminal connection height: H1= 16mm; H2= 21mm
- Over Voltage Tripping: 280V ± 5%
- Connection Capacity: Flexible Conductor 10mm²; Rigid Conductor: 16mm²
- Installation: On symmetrical DIN Rail 35mm; Panel mounting
Download datasheet: LA225 Datasheet
-
Two Pole RCD MCB RCBO 32A 4.5Ka
- Two Pole
- Rated short-circuit breaking capacity: 4.5kA
- Rated Current: 32A
- Degree of Protection: IP20
- Effectively protects electric equipment against insulating failure
Download datasheet: LA232 Datasheet